alcon sa60at a constant

[404]: data by Dres. [85]: data by O.Hauptman, MD, Australia [332]: data by Dr. Peter Stewart, Maroochydore, QLD Australia Alcon SA60AT AcrySof Single-Piece Acrylic Foldable IOL, UV-Absorbing Posterior Chamber Lens, 13.0mm Length, 6.0mm Biconvex Optic, Planar Haptics Item Past Expiration 033310/2 Features Condition: New Country of origin : United States Ships From : United States Brand Product Brand: Alcon 4.00 Average star rating 1 review 5 Stars 0 4 Stars 1 3 Stars 0 Results: Brazil [60]: data by V.Centurion, MD, Brazil [95]; data by Dr.R.Wertheimer,Mnchen, Germany [32]: data by Dr.V.Hessemer, Darmstadt, Germany [123]: data by Dr.J.Bosche, Diepholz, Germany Last Revision: Oct 31, 2016 WH, (*): A-const taken from: Mohr A, Hengerer F, Eckardt C: Retropupillare Fixation der Irisklauenlinse bei Aphakie. [323]: data by Dr. Katrin Hermes, Oranienburg, Germany [108]: data by Dr.R.Zimmer, Lbau, Germany [85]: data by O.Hauptman, MD, Australia 1stQ Basis Z A=118.0 a0=0.325 a1=0.255 a2=0.141 pACD=5.01 sf=1.25 A=118.1 A=118.3 672 [49],[223],[224],[84],[33],[245],[122],[246],[271],[272],[286],[350] ZEISS CT SPHERIS 203(P) (XL Stabi, XL Stabi Sky) A=118.0 a0=1.05 a1=0.40 a2=0.10 pACD=5.23 sf=1.47 A=118.5 A=118.8 98 [37] Subgroups of cases were studied prospectively to evaluate 3 factors: same-day incision competence after implantation (postoperative intraoperative pressure [IOP], 107 cases); 2- to 5-week A-constant validation (200 cases); 1-day, 2-week, and 1- and 5-month descriptions of optic centration with respect to pupil and capsule anatomy (79 cases); and a 1-day versus 9-month photographic comparison of IOL centration (70 cases). In vitro and schematic model eye assessment of glare or positive dysphotopsia-type photic phenomena: Comparisonof a new material IOL to other monofocal IOLs. If you continue to use this site we will assume that you are happy with it. [215]: data by Dr.D.Alzheimer, Germany Oculentis L-302 discontinued A=118.5 a0= 1.30 a1=0.40 a2=0.10 pACD=5.45 sf=1.70 A=118.9 A=119.2 195 [51],[87],[105],[116],[117],[118] L.Neubauer MD(Mnchen, Germany), Our services and technology are covered by the partnering members with the end goal of making healthcare more affordable and transparent. J Cataract Refract Surg. Eyeol LW5752R A=118.0 a0=1.27 a1=0.40 a2=0.10 pACD=5.46 sf=1.71 A=118.9 A=119.2 61 [343] [102]: data by Fritz Ruck GmbH, Eschweiler, Germany [390]: data by Dr. C. Kloos & Dr. B. Pleisch, Augenzentrum Wil, Switzerland [231]: data by Dr.A.Bach, Schwerin, Germany A-constant validation. Similarly, the Design Factor of Tecnis ZCB00 is 4. [235]: data by Th.Hofmann, Binningen, Switzerland [246]: data by Dr.Marita Amm, Erlangen, Germany Alcon MA60MA (-diopters) A=118.9 a0= -4.22 a1=0.40 a2=0.10 pACD= -5.52 sf= -7.08 A=103.6 A=119.1 39 [143],[18],[389] [216]: data by Dr.S.Bttmann, Ladenburg, Germany different surgeons from Eye Clinic Kln-Merheim, Germany AMO Tecnis ZMB00 A=118.8 a0= -1.013 a1=0.199 a2=0.242 pACD=5.89 sf=2.12 A=119.5 A=119.8 184 [294],[71],[333],[334],[335],[336],[43] Alcon ReSTOR SN6AD1/3 (India) A=119.1 a0=1.35 a1=0.40 a2=0.10 pACD=5.57 sf=1.80 A=119.0 A=119.3 66 [314] AMO Tecnis Z9002 A=118.7 a0= -1.201 a1=0.102 a2=0.246 pACD=5.46 sf=1.67 A=118.8 A=119.0 1275 [109],[139],[140],[19],[103],[104],[72],[98],[232],[234],[239] [396]: data by Dr. A. Liermann, Neustadt / Weinstrasse, Germany [209]: data by Dr.K.Meyer-Hamme, Ludwigsburg, Germany [230]: data by Dr.A.Krmer, Lbeck, Germany i-Medical i-Flex A=118.8 a0=1.05 a1=0.40 a2=0.10 pACD=5.23 sf=1.46 A=118.4 A=118.6 184 [74] Aaren Scientific OPTIVIS A=118.1 a0=0.75 a1=0.40 a2=0.10 pACD=4.97 sf=1.20 A=118.0 A=118.2 71 [237],[291],[243] Visional RBAG A=120.2 a0=1.88 a1=0.40 a2=0.10 pACD=6.04 sf=2.28 A=119.7 A=120.5 64 [31] [293]: data by Tomasz Trzos, Grlitz, Germany [284]: data by Prof.Dr.G.Alessio, Bari,Italy Oshika T, Fujita Y, Inamura M, Miyata K. Mid-term and long-term clinical assessments of a new 1-piece hydrophobic acrylic IOL with hydroxyethylmeth-acrylate. HumanOptics Diff-aA(Y) A=118.4 a0=1.28 a1=0.40 a2=0.10 pACD=5.50 sf=1.73 A=118.9 A=119.2 87 [155],[36 [130]: data by D.L.Cooke MD, St.Joseph, MI, USA [105]: data by Wavelight AG, Berlin, Germany [399]: data by Afidera GmbH, Berlin, Germany The SRK T formula is a third generation formula, described in 1990 by John Retzlaff, Kraff and Sanders [6]. biometry and partial coherence interferometry for IOL calculation according to [290]: data by Dr. J.M. [174]: data by Dr.S.Kretschmar, Bautzen, Germany [319]: data by Dr. Antoni Salvador Playa, Terrassa, Spain [401]: data by Dr. F. Kretz, Rheine, Grmany [396]: data by Dr. A. Liermann, Neustadt / Weinstrasse, Germany [393]: data by Dres Becker, Cordero, Maruniak. [403]: data by Prof. Dr. Rozsival, Kralove, Czech Republic [41]: data by C.Suto, MD, Tokyo, Japan A=116.8 (*) a0= -0.25 a1=0.40 a2=0.10 pACD=4.34 sf=0.54 A=116.9 A=116.8 20 AMO Verisyse 50 aph.retropup. Technoko TA625 A=118.0 a0=1.17 a1=0.40 a2=0.10 pACD=5.32 sf=1.59 A=118.7 A=119.1 40 [54] 1 review Write a review. [247]: data by Dr.Franc Salamun, Nova Gorica, Slovenia [75]: data by Dr.U.Heuer, Hamburg, Germany [65]: data by Dr.M.V.Partyngl, Wil, Switzerland Epub 2015 May 7. [270]: data by Dr.A.Rosa Almeida, Ipatinga, Brazil [297]: data by Carl Zeiss Meditec AG [84]: data by Dr.W.Bachmann,Aschaffenburg, Germany [6]: based on data by different surgeons from Eye Clinic Kln-Merheim, Germany [252]: data by Dr.N.Reus, Rotterdam, The Netherlands Since they reflect the special hardware and processing conditions of the instrument type applied for data acquisition, [393]: data by Dres Becker, Cordero, Maruniak. INDICATION: The ClareonAspheric Hydrophobic Acrylic IOLs include the Clareon Aspheric and Clareon Aspheric Toric IOLs and are indicated for primary implantation in the capsular bag in the posterior chamber of the eye for the visual correction of aphakia in adult patients in whom a cataractous lens has been removed. [328]: data by Dres. [299]: data by Cataract Service, Moorfields Eye Hospital, London, UK Lane S, Collins S, Das KK, Maass S, Thatthamla I, Schatz H, Van Noy S, Jain R. Evaluation of intraocular lens mechanical stability. different surgeons from Eye Clinic Kln-Merheim, Germany [335]: data by Dr. Ralf Gerl, Ahaus, Germany SIFI Mini Well A=118.6 a0=1.33 a1=0.40 a2=0.10 pACD=5.52 sf=1.73 A=118.8 A=119.1 49 [360] [255]: data by Dr..Kavalcioglu, Istanbul, Turkey [15]: data by J.Chvojkova, MD, Prague, Czech Republic [381]: data by Dr. KIM Joung Mok, Seoul, South Korea Haigis, Graefes Arch Clin Exp Ophthalmol (2000) 238:765-773 The effects of this aspheric [289]: data by HSK Wiesbaden, Germany [202]: data by M.Franke, Kirchberg, Germany The Alcon MA60AL 3-piece acrylic optic and haptic intraocular lens (IOL) was introduced in January 1995. Eyeol Hyflex A=118.8 a0=1.54 a1=0.40 a2=0.10 pACD=5.69 sf=1.93 A=119.2 A=119.5 49 [325] Hanita BunnyLens MF A=118.5 a0=1.22 a1=0.40 a2=0.10 pACD=5.50 sf=1.76 A=118.9 A=119.0 36 [338] [81]: data by Dr.T.Laube, Duesseldorf, Germany [25]: data by Dr.U.Reinking, Salzkotten, Germany Polytech Polylens AS61 A=118.2 a0= -2.993 a1=0.189 a2=0.294 pACD=5.00 sf=1.24 A=118.1 A=118.3 429 [315] Polytech Polylens H30(Y30) (+) A=118.2 a0=1.34 a1=0.40 a2=0.10 pACD=5.53 sf=1.75 A=118.9 A=119.1 181 [138],[81],[106] Domilens Flex65L discontinued A=118.4 a0=1.45 a1=0.40 a2=0.10 pACD=5.68 sf=1.88 A=118.9 A=118.9 50 [2],[18] [333]: data by Dr. Alfredo Ferrer, Denia, Spain Description. [383]: data by Dr. KIM Jun Heon, Seoul, South Korea [271]: data by Dr.G.Sauder, Stuttgart, Germany [237]: data by Dr.Matteo Piovella, Monza, Italy Alcon Toric SN6AT(2-9) A=119.0 a0= -0.323 a1=0.213 a2=0.208 pACD=5.81 sf=1.98 A=119.2 A=119.3 584 [55],[302] [6]: based on data by different surgeons from Eye Clinic Kln-Merheim, Germany There were no cases of decentration greater than 1.0 mm in either optic centration subgroup. C.Grenauer-Kloevekorn, Halle, Germany [12]: data by E.Frieling, MD,Mnchen, Germany [134]: data by Dr.Chr.Chassain, Montpellier, France ALCON SA60AT Intraocular Lens 25.0D, Length 13.0mm, Optic 6.00mm SRK/T Optical A-Constant : 118.7 SRK/T Ultrasound A-Constant :118.3 All items listed are on inventory. [301]: data by Prof. Dr. V.Jasinskas, Kaunas, Lithuania

Bonnie Lee Bakley, Articles A